Event
- Event ID
- 1185
- Quality
- Description
- A truck carrying hydrogen cylinders on a village road had to execute an emergency manoeuvre to avoid an oncoming vehicle which had crossed the centre line. The truck hit the curb and overturned. The cylinders were scattered on the road, one of them lost its protection due to the impact with the ground damaging the valve. Hydrogen leaked and ignited.
- Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- Fire (No additional details provided)
- Macro-region
- Asia
- Country
- Japan
- Date
- Main component involved?
- Valve (Generic)
- How was it involved?
- Rupture
- Initiating cause
- Impact, Rollover, Crash
- Root causes
- Root CAUSE analysis
- INITIATING CAUSE was a traffic accident.
In absence of information on driver, the ROOT CAUSE is attributed generically to a human error (wrong manoeuvre).
Facility
- Application
- Hydrogen Transport And Distribution
- Sub-application
- CGH2 cylinders truck
- Hydrogen supply chain stage
- Hydrogen Transport (No additional details provided)
- All components affected
- valve, cylinders cap.
- Location type
- Open
- Operational condition
Emergency & Consequences
- Number of injured persons
- 0
- Number of fatalities
- 1
Event Nature
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Presumed ignition source
- Not reported
References
- Reference & weblink
High Pressure Gas Accident Cases Database of the KHK (High Pressure Gas Safety Association): <br />
https://www.khk.or.jp/public_information/incident_investigation/hpg_inc… />
(accessed May 2025)
JRC assessment
- Sources categories
- KHK