Skip to main content
Clean Hydrogen Partnership

collision of a LH2 trailer

Event

Event ID
1118
Quality
Description
Driver lost control of vehicle ran off highway on right side into wooded area. The front vessel pressure gauge was knocked off the trailer tank. A small amount of gaseous hydrogen was vented until the gauge shut off valve was closed.
Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
Leak No Ignition (No additional details provided)
Macro-region
North America
Country
United States
Date
Main component involved?
Joint/Connection (Gauge)
How was it involved?
Rupture
Initiating cause
Impact, Rollover, Crash
Root causes
Root CAUSE analysis
INITIATING CAUSE was a traffic accident.
In absence of information on driver, the ROOT CAUSE is attributed generically to a human error (wrong manoeuvre).

Facility

Application
Hydrogen Transport And Distribution
Sub-application
LH2 tanker
Hydrogen supply chain stage
Hydrogen Transport (No additional details provided)
All components affected
Auxiliary Valve; pressure gauge
Location type
Open
Operational condition
Pre-event occurrences
Damage after crash

Emergency & Consequences

Number of injured persons
0
Number of fatalities
0
Environmental damage
0
Currency
US$
Property loss (onsite)
95010
Property loss (offsite)
0
Post-event summary
The major loss was probably related to the trailer/truck crash damages. Approximately 200 kg of hydrogen were released.

Event Nature

Release type
gas
Involved substances (% vol)
H2 100%
Released amount
200.58970476911
Presumed ignition source
No ignition

References

Reference & weblink

Incident I-2002101097 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: <br />
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%… />
(accessed September 2024)

JRC assessment