Explosion at a gas manufacturer

Event

Event ID
1111
Quality
Description
The explosion occurred at the premises of a manufacturer of special gases. A hydrogen trailer in the trailer parking lot had leaked hydrogen, which then ignited. The explosion was clearly audible in the neighbourhood. A fire engulfing other combustible materials, such as the tyres of the trailer, followed the explosion. The smoke cloud was visible from far.
The plant fire brigade was immediately on site and brought the risk under control, by fighting the fire and keeping cold the surroundings. No one was injured. From the pictures released by the sources, it can be deduced that a full bundle of vertically structured hydrogen bottles burned down, affecting also two adjacent trailers carrying horizontal tubes. Some of the bottles of the burned down bundle are seen metres away from the original location, one being almost completely charcoaled .
Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
Europe
Country
Germany
Date
Main component involved?
Cgh2 Tube Trailer
How was it involved?
Leak & Formation Of A Flammable H2-Air Mixture
Initiating cause
Unknown
Root causes
Unknown (No additional details provided)

Facility

Application
Hydrogen Production
Sub-application
Speciality gas production
Hydrogen supply chain stage
Hydrogen Transport (No additional details provided)
All components affected
trailer
Location type
Open
Location description
Industrial Area
Operational condition
Description of the facility/unit/process/substances
DESCRIPTION OF THE FACILITY
The company produces oxygen, hydrogen, nitrogen, carbon monoxide and several other special gases. It supplies hydrogen to several HRS.

DESCRIPTION OF THE TRAILER
The trailer was of a new type, taken in operation less than one year before.
Its total hydrogen capacity could only be estimated in a range between 500 to 1000 kg.

Emergency & Consequences

Number of injured persons
0
Number of fatalities
0
Environmental damage
0
Property loss (offsite)
0
Post-event summary
no injury. Property losses unknown.
The explosion was clearly audible in the immediate vicinity as a loud bang, which also damaged some nearby window panes. The subsequent fire on the trailer and its tyres produced a large cloud of smoke.
Hydrogen off takers, especially the refuelling stations (including a hydrogen train service), experienced shortage of hydrogen delivery for at least 14 days.

Event Nature

Release type
gas
Involved substances (% vol)
H2 100%
Presumed ignition source
Not reported

References

Reference & weblink

Press statement of the company:<br />
https://www.infraleuna.de/news/news-detail/verpuffung-auf-dem-gelaende-… />
(accessed September 2024)

A summary was shared by NOW in a presentation of 8 Octobr 2024

Addional sources & pictures

JRC assessment