Event
- Event ID
- 949
- Quality
- Description
- A syngas leak (hydrogen + methane) occurred at exit of the ammonia production reactor and led to an explosion followed by a fire.
The start point of the sequence of events was the syngas at the reactor outlet reaching an abnormal pressure of 150 bar and a temperature of 300°C. This caused a flange seal to move, causing the gases to leak.
The accident caused a pressure waves and fire observed on the installations over a distance of 450 metres. - Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- Macro-region
- Europe
- Country
- Slovakia
- Date
- Root causes
- Root CAUSE analysis
- The INITIATING cause was an overpressure on a flange, causing its loss of confinement. The sources do not mention the reason(s) for the unexpectedly high-pressure value, but it could be assumed that it was an exceptional event, but not completely unexpected.
From the corrective actions adopted it appears an absence of a risk assessment based on the possibility of ignition of flammable gases at the ammonia reactor, the usage of a inadequate components (flange) and the lack of effective communication of an alarm to personnel. These points hint at ROOT CAUSES related to inadequate (safety) design and risk management.
Facility
- Application
- Chemical Industry
- Sub-application
- Fertilisers production
- Hydrogen supply chain stage
- All components affected
- ammonia reactor
- Location type
- Open
- Location description
- Industrial Area
- Operational condition
- Description of the facility/unit/process/substances
- DESCRIPTION OF THE COMPONENTS
The pipe diameter at the exit of the ammonia reactor had a diameter of 300 mm (DN300). The flange used on this pipe was a model with a lenticular seal between the clamp and the tube, screwed to the flange by bolts.
Emergency & Consequences
- Number of injured persons
- 5
- Number of fatalities
- 0
- Currency
- Euros
- Property loss (onsite)
- 12000000
- Property loss (offsite)
- 0
- Post-event summary
- The accident caused 5 injuries. Material damage due to the pressure waves and fire was observed on the installations over a distance of 450 metres. The consequences for the site were estimated at €12,000,000.
Lesson Learnt
- Corrective Measures
After the accident, the operator considered the following measures:
1) to conduct an explosion risk study in areas where ammonia or flammable gases are handled and in areas where an explosion has already occurred;
2) the installation of an personnel alert system and an evacuation procedure in the event of a process failure that could lead to an explosion;
3) the replacement of the flanges by a model more adapted to over-pressure hazard.
Event Nature
- Release type
- gas mixture (syngas)
- Involved substances (% vol)
- syngas
- Release duration
- unknown
- Actual pressure (MPa)
- 15
- Design pressure (MPa)
- < 15
- Presumed ignition source
- Not reported
References
- Reference & weblink
Event description in the French database ARIA<br />
https://www.aria.developpement-durable.gouv.fr/accident/50265/<br />
(accessed October 2020)<br />Event description in the European database eMARS<br />
https://emars.jrc.ec.europa.eu/en/emars/accident/view/f8c4af35-d462-cb6… />
(accessed October 2025)<br />
JRC assessment
- Sources categories
- ARIA