Event
- Event ID
- 828
- Quality
- Description
- In a chemical plant, a fire broke out on a hydrogen column of an ammonia manufacturing unit.
The internal security service extinguishes the fire with powder and nitrogen injection.
The unit was cooled with water. - Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- Fire (No additional details provided)
- Macro-region
- Europe
- Country
- France
- Date
- Main component involved?
- Reactor / Oven / Furnace / Test Chamber
- How was it involved?
- Leak & Formation Of A Flammable H2-Air Mixture
- Initiating cause
- Unknown
- Root causes
- Unknown (No additional details provided)
Facility
- Application
- Chemical Industry
- Sub-application
- Ammonia production
- Hydrogen supply chain stage
- All components affected
- hydrogen column, ammonia reactor
- Location type
- Open
- Location description
- Industrial Area
- Operational condition
Emergency & Consequences
- Number of injured persons
- 0
- Number of fatalities
- 0
Event Nature
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Presumed ignition source
- Not reported
References
- Reference & weblink
ARIA data base <br />
event no. 3383
JRC assessment
- Sources categories
- ARIA