Skip to main content
Clean Hydrogen Partnership

Release during transport of CGH2 cylinders

Event

Event ID
822
Quality
Description
A leak occurred in a vehicle carrying 218 cylinders of hydrogen. The contents of 28 cylinders, 90 m³ of hydrogen, escaped.
A security perimeter was set up with stop of the road and rail traffic.
Event Initiating system
Classification of the physical effects
Unignited Hydrogen Release
Nature of the consequences
Leak No Ignition (No additional details provided)
Macro-region
Europe
Country
France
Date
Main component involved?
Joint/Connection
How was it involved?
Leak & Formation Of A Flammable H2-Air Mixture
Initiating cause
Unknown
Root causes
Unknown (No additional details provided)

Facility

Application
Hydrogen Transport And Distribution
Sub-application
CGH2 cylinders truck
Hydrogen supply chain stage
Hydrogen Transport (No additional details provided)
All components affected
cylinders
Location type
Open
Operational condition
Pre-event occurrences
The capacity in mass of hydrogen was calcualted assuming that the value of 90 m3 provided by the source represents a volume of hydrogen at standard conditions.

Emergency & Consequences

Number of injured persons
0
Number of fatalities
0
Post-event summary
90 m³ (ca. 8 kg) of hydrogen, escaped

A security perimeter was set up with stop of the road and rail traffic.

Event Nature

Release type
gas
Involved substances (% vol)
H2 100%
Released amount
7.5
Actual pressure (MPa)
20
Presumed ignition source
No ignition

References

Reference & weblink

ARIA data base <br />
event no. 1361

JRC assessment