Event
- Event ID
- 648
- Quality
- Description
- A weld on a 1 inch diameter instrument tapping from a Octafiner reactor overhead line fractured, resulting in a small but intense fire, lasting about 50 minutes until the unit was nitrogen purged.
The fire was always under control and the fire fighting effort was directed solely to cooling the surrounding metal with fire steam lances. Plant Inspection reported that the failure was due to hydrogen embrittlement of the heat affected zone of the tapping and probably resulted from improper or no stress relieving of the connection during construction. - Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- Fire (No additional details provided)
- Macro-region
- Asia
- Country
- Japan
- Date
- Main component involved?
- Pipe
- How was it involved?
- Rupture & Formation Of A Flammable H2-Hc-Air Mixture
- Root causes
- Root CAUSE analysis
- The INITIATING CAUSE was the failure of a weld on an instrument line of the reactor.
The fracture was due to hydrogen embrittlement, probably worsened by the presence of non-design stress probably due to an inadequate heat treatment for relieving welding stress.
The ROOT CAUSE could then be attributed to manufacturing shortcoming, possibly together with choice of non-optimal materials. Nothing is known on the inspection procedures which could identify degradation in its early stage.
Facility
- Application
- Chemical Industry
- Sub-application
- Hydroisomerisation process
- Hydrogen supply chain stage
- All components affected
- octafining reactor pipe, weld
- Location type
- Unknown
- Location description
- Industrial Area
- Operational condition
- Pre-event occurrences
- PRCOESS
- Description of the facility/unit/process/substances
- DESCRIPTION OF THE PROCESS
The Octafiner process is catalytic hydrogenation process. It is a patented technology aiming at upgrading heavy oils and distillates into lighter, higher-value products. This process is used to remove sulfur, nitrogen, and metals, and to saturate aromatics, which improves the quality of the product.
Emergency & Consequences
- Number of injured persons
- 0
- Number of fatalities
- 0
- Environmental damage
- 0
Lesson Learnt
- Lesson Learnt
The emergency measures taken were effective in containing the emergency and avoiding escalation. Probably the fact that the fire was small helped in not affecting surrounding component. The measure which solved the emergency was the purging by nitrogen, which stopped the fire.
Event Nature
- Release type
- gas mixture
- Involved substances (% vol)
- unknown
- Presumed ignition source
- Not reported
References
- Reference & weblink
Event of the UK database ICHEME.<br />
https://www.icheme.org/knowledge/safety-centre/resources/accident-data/
JRC assessment
- Sources categories
- ICHEME