Event
- Event ID
- 376
- Quality
- Description
- A liquid hydrogen tanker was parked at a parking place. The vacuum on the tanker vessel deteriorated causing inner container pressure increase. When the inner container pressure reached the nominal pressure limit, the safety relief valve automatically vented the trailer.
The vessel was allowed to vent, to allow to reduce the internal pressure to a value safe for transport back to home terminal. The tanker was taken out of service and vacuum problem repaired. - Event Initiating system
- Classification of the physical effects
- Unignited Hydrogen Release
- Nature of the consequences
- Leak No Ignition (No additional details provided)
- Macro-region
- North America
- Country
- United States
- Date
- Main component involved?
- Prd (Valve)
- How was it involved?
- Correct Activation
- Initiating cause
- Over-Pressurisation (Thermal Insulation Degradation)
- Root causes
- Root CAUSE analysis
- The INITIAL CAUSE was the activation of the pressure relief valve due to increased internal pressure of the cryogenic vessel.
The ROOT CAUSE was the reduction of the thermal isolation capacity of the isolation external shell of the vessel, due to a deterioration of the vacuum.
Facility
- Application
- Hydrogen Transport And Distribution
- Sub-application
- LH2 tanker
- Hydrogen supply chain stage
- Hydrogen Transport (No additional details provided)
- All components affected
- vent valve
- Operational condition
Emergency & Consequences
- Number of injured persons
- 0
- Number of fatalities
- 0
- Environmental damage
- 0
- Currency
- US$
- Property loss (onsite)
- 384
- Property loss (offsite)
- 0
- Post-event summary
- 25 kg of hydrogen were released
Lesson Learnt
- Lesson Learnt
The safety measures in place worked as expected. Releasing (‘’venting”) hydrogen to reduce internal pressure is a standard procedure when travelling. Usually, drivers are able to monitors vessel pressure by regular inspection and therefore perform a venting before the pressures reach the set value of the pressure relief valve. In this case, probably, the stop at the parking place had been too long to detect early enough the thermal isolation deterioration of the vessel, and avoid the valve activation.
Event Nature
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Released amount
- 6.6994700984103
- Presumed ignition source
- No ignition
References
- Reference & weblink
Report I-1993050528 of the US Pipeline and Hazardous Materials Safety Administration PHMSA: <br />
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%… />
(accessed September 2024)
JRC assessment
- Sources categories
- PHMSA