Fire on a CGH2 tube trailer

Event

Event ID
261
Quality
Description
While driving on a highway, the driver of a CGH2 tube trailer was notified by another driver of the smoke coming from his trailer. The CGH2 tube trailer parked in a place considered safe, inspected the trailer and found the sides hot. After having called the emergency services, he unhooked the tractor from the trailer and moved the tractor away from the trailer. At this time, the first police officer arrived. The hazmat contractor in charge of the clean up arrived more than 3 hours later. Throughout all this time, it is assumed that the fire continued, but the report mentions only the contamination of the ground due to the exposure of the steel containment floor of the trailer to the fire. The trailer was disposed, probably because very damaged. No cause reported.
Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Fire (No additional details provided)
Macro-region
North America
Country
United States
Date
Main component involved?
Valve (Generic)
How was it involved?
Leak & Formation Of A Flammable H2-Air Mixture
Initiating cause
Unknown
Root causes
Unknown (No additional details provided)

Facility

Application
Hydrogen Transport And Distribution
Sub-application
CGH2 tube trailer
Hydrogen supply chain stage
Hydrogen Transport (No additional details provided)
All components affected
unknown
Location type
Open
Operational condition
Description of the facility/unit/process/substances
The nominal pressure is not povided. Nevertheless, from the website of the trailer manufacturer, it can be assumed that the trailer was carrying type I steel tubes wtih a nominal pressure of 180 bar

Emergency & Consequences

Number of injured persons
0
Number of fatalities
0
Environmental damage
0
Currency
US$
Property loss (onsite)
714000
Property loss (offsite)
0
Emergency action
As a precaution, emergency crews evacuated the immediate area. A team from the trailer company was dispatched to the scene. Before up-righting the trailer, they vented the remaining hydrogen through the vent stack and purged the tubes with nitrogen. There was no fire.

Event Nature

Release type
gas
Involved substances (% vol)
H2 100%
Actual pressure (MPa)
18
Design pressure (MPa)
18
Presumed ignition source
Not reported

References

Reference & weblink

Incident I-1997110950 of the US Pipeline and Hazardous Materials Safety Administration PHMSA (multiple reports because of more gases, but no pdf report): <br />
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages&PortalPath=%… />
(accessed September 2024)

JRC assessment