Event
- Event ID
- 200
- Quality
- Description
- An unexplained loss of vacuum resulted in the release of all the transported hydrogen by manual venting and and opening of the relief valve.
[Zalosh and Short, 1978] - Event Initiating system
- Classification of the physical effects
- Unignited Hydrogen Release
- Nature of the consequences
- Leak No Ignition (No additional details provided)
- Macro-region
- North America
- Country
- United States
- Date
- Main component involved?
- Lh2 Tanker
- How was it involved?
- Correct Activation
- Initiating cause
- Over-Pressurisation (Thermal Insulation Degradation)
- Root causes
- Root CAUSE analysis
- The INITIATING CAUSE was the deterioration of the vacuum and therefore of thermal insulation of the cryogenic tank.
The ROOT CAUSE unknown.
Facility
- Application
- Hydrogen Transport And Distribution
- Sub-application
- LH2 tanker
- Hydrogen supply chain stage
- Hydrogen Transport (No additional details provided)
- All components affected
- vacuum thermal insulation
- Location type
- Open
- Operational condition
Emergency & Consequences
- Number of injured persons
- 0
- Number of fatalities
- 0
- Currency
- US$
- Property loss (onsite)
- 1700
- Property loss (offsite)
- 0
- Emergency action
- Police and highway patrol interrupted traffic in both directions and establish a security perimeter. The prefecture was informed, firemen were called to stop the fire, which was brought under control two and a half hours later. The traffic was back on the road six hours after the start.
Lesson Learnt
- Lesson Learnt
Zalosh et al (see references), concluded their analysis of hydrogen transportation accidents till 1978 with the following conclusions:
"Finally, an encouraging aspect of the transportation incident compilation is that 71% of the hydrogen releases did not lead to an ignition. ... The relatively few ignitions may be due to either to lack of ignition sources or to the rapid dispersal of hydrogen into the atmosphere. In any event, the accident data provide further incentive t o transport , transfer and store hydrogen outdoors away from occupied areas."
Event Nature
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Presumed ignition source
- No ignition
References
- Reference & weblink
Extract from Table III of Appendix A of Zalosh and Short<br />
COMPARATIVE ANALYSIS OF HYDROGEN FIRE AND EXPLOSION INCIDENTS<br />
Quarterly Report No. 2 for Period December 1, 1977 - February 28, 1978<br />
https://www.osti.gov/biblio/6566131<br />
(accessed September 2020)Event incident I-1974120148 of the PHMSA database (Pipeline and Hazardous Materials Safety Administration, 1996),<br />
https://portal.phmsa.dot.gov/analytics/saw.dll?Portalpages<br />
(accessed September 2024)
JRC assessment
- Sources categories
- Zalosh