Description
The event took place at the metal sheet pre-heating oven of a galvanization unit. This was using a mixture of hydrogen and nitrogen to form a reducing atmosphere and avoid oxydation of the metallic sheets.
The zinc crucible’s draining operations was completed and the hydrogen purge operation which had been started 6 hours earlier, was underway when an explosion happened.
Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
Europe
Country
France
Date
Main component involved?
Reactor / Oven / Furnace / Test Chamber
How was it involved?
Internal Explosion (H2-Air Mixture)
Initiating cause
Wrong Operation
Root causes
Root CAUSE analysis
The INITIATING CAUSE was due to the fact that the valve on the backup hydrogen tank and the by-pass on the furnace’s supply line were not closed. A hot spot in the oven probably ignited the explosive atmosphere.

No information is available on the ROOT CAUSE, but probably related to shortcomings of the procedures and/or an operator error.

Facility

Application
Steel And Metals Industry
Sub-application
generic metal processing
Hydrogen supply chain stage
All components affected
Pre-heating oven for metal sheets
Location type
Unknown
Location description
Industrial Area
Operational condition
Pre-event occurrences
The oven had been shut down the previous evening for annual maintenance work.

Emergency & Consequences

Number of injured persons
0
Number of fatalities
0
Post-event summary
The four employees present were not injured. No impact outside the site was reported.

Lesson Learnt

Corrective Measures
Following the accident, the operator modified the procedures concerning these operations by:
(1) Blinding of the by-pass and leak test,
(2) modifying the valve of the back-up H2 circuit to allow lock-out capability.

Event Nature

Release type
gas mixture
Involved substances (% vol)
H2
N2
Release duration
unknown
Presumed ignition source
Not reported

References

Reference & weblink

Event No, 30365 of the French database ARIA<br />
https://www.aria.developpement-durable.gouv.fr/accident/30365/<br />
(accessed December 2020)

JRC assessment