Skip to main content
Clean Hydrogen Partnership

Event

Event ID
411
Quality
Description
An oil leak in a hydrogen compressor was identified by a technician performing regular maintenance on the compressor.
The oil leak had caused a contamination of the entire hydrogen system from the compressor to the filling nozzle.
Event Initiating system
Classification of the physical effects
No Hydrogen Release
Nature of the consequences
Macro-region
Europe
Country
Norway
Date
Main component involved?
Compressor / Booster / Pump
How was it involved?
Leak
Initiating cause
Unknown
Root causes
Unknown (No additional details provided)
Root CAUSE analysis
The contamination was noted during maintenance, but occurred before, during normal operation.

Facility

Application
Hydrogen Refuelling Station
Sub-application
hydrogen compression
Hydrogen supply chain stage
Hydrogen Compression (No additional details provided)
All components affected
oil, compressor membrane,
dispenser,
filling nozzle
Location type
Unknown
Operational condition
Pre-event occurrences
The contamination was noted during maintenance, but occurred during before, during normal operation.

Emergency & Consequences

Number of injured persons
0
Number of fatalities
0
Post-event summary
Air Liquide stopped the production of Hydrogen and the filling of the buses and the entire system from compressor to the filling nozzle was taken apart and cleaned.

Lesson Learnt

Corrective Measures
An oil leak detection system (coalescent filter and optical sensor), was installed.

Event Nature

Release type
no release
Presumed ignition source
No release

References

Reference & weblink

Report available but confidential

JRC assessment