Skip to main content
Clean Hydrogen Partnership

Fire in a benzene plant

Event

Event ID
623
Quality
Description
During repairs of a heat exchanger in a benzene plant, a mixed gas (methane and hydrogen) contained in the cold box attached to the exchanger leaked and caught fire from a welding spark. The exchanger was severely damaged by the fire.
Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Fire (No additional details provided)
Macro-region
Asia
Date
Main component involved?
Heat Exchanger (Cold Box)
How was it involved?
Leak & Formation Of A Flammable H2-Ch4-Mixture
Initiating cause
Wrong Operation
Root causes
Root CAUSE analysis

The ROOT CAUSE was the failure to close a valve with a blind plate, before starting the repairs. The cold box was not properly closed.

Facility

Application
Petrochemical Industry
Sub-application
Benzene production
Hydrogen supply chain stage
All components affected
Heat exchanger
Location type
Unknown
Location description
Industrial Area
Operational condition

Emergency & Consequences

Number of injured persons
0
Number of fatalities
0
Post-event summary
The exchanger was severely damaged by the fire.

Event Nature

Release type
gas mixture
Involved substances (% vol)
H2, CH4
Presumed ignition source
Welding

References

Reference & weblink

Event nr 10256 of the UK database ICHEME in PDF format.<br />
https://www.icheme.org/knowledge/safety-centre/resources/accident-data/… />
(accessed October 2020)<br />

JRC assessment