Event
- Event ID
- 69
- Quality
- Description
- This incident occurred at a waste water tank of an unspecified chemical plant. An explosive atmosphere formed inside the wastewater tank due to the accidental production of hydrogen. This occurred either during wastewater treatment or due to the reaction of excess sodium borohydride from the remaining wastewater in the tank with additional wastewater added to the tank later.
The hydrogen-air explosive atmosphere was forced through an overflow pipe and through a water seal and released into the surrounding area, where it was ignited by manual work. Subsequently, a flashback occurred through the overflow pipe into the wastewater tank, resulting in an explosion which destroyed the tank. - Event Initiating system
- Classification of the physical effects
- Hydrogen Release and Ignition
- Nature of the consequences
- Macro-region
- Europe
- Country
- Germany
- Date
- Main component involved?
- Chemical Storage Tank (Waste)
- How was it involved?
- Rupture & Formation Of A Flammable H2-Air Mixture
- Initiating cause
- Accidental Hydrogen Formation
- Root causes
- Root CAUSE analysis
- The INITIATING CAUSE was an accidental formation of hydrogen by a chemical reaction.
The ROOT CAUSE was the lack of effective monitoring and control of the process values, specifically the lack of pH adjustment during filling of the wastewater tank. This hint at shortcoming of the operative procedures, of risk assessment and/or of proper training of operators.
Facility
- Application
- Chemical Industry
- Sub-application
- waste management
- Hydrogen supply chain stage
- Hydrogen Transport (No additional details provided)
- All components affected
- water seal,
oveflow pipe, sodium borohydride tank - Location type
- Open
- Location description
- Industrial Area
- Operational condition
Emergency & Consequences
- Number of injured persons
- 13
- Number of fatalities
- 0
- Currency
- Euro
- Property loss (onsite)
- 1000000
- Post-event summary
- The tank and othe plant componets were destroyed by the explosion and subsequent fire.
Lesson Learnt
- Corrective Measures
As preventive measure, the wastewater treatment process was modified.
As control measures, (i) a HAZOP analysis of wastewater treatment was implemented and wastewater flows were monitored.
Event Nature
- Release type
- gas
- Involved substances (% vol)
- H2 100%
- Presumed ignition source
- Mechanical sparks
References
- Reference & weblink
Event from German database ZEMA<br />
https://www.infosis.uba.de/index.php/de/site/2854/zema/index/3223.html<… />
(accessed December 2024)
JRC assessment
- Sources categories
- ZEMA