Explosion in an electrical appliance manufacturing plant.

Event

Event ID
964
Quality
Description
Hydrogen was accidentally produced inside the sealed container containing a used battery. The gas, along 6 days deformed the container. Firefighters equipped with breathing apparatus opened the container remotely triggering a considerable explosion.
Event Initiating system
Classification of the physical effects
Hydrogen Release and Ignition
Nature of the consequences
Macro-region
Europe
Country
France
Date
Root causes
Root CAUSE analysis
The ARIA report does not identifies any cause. It is known that lead-acid batteries and in-metals batteries can accidentally release gaseous hydrogen .

Facility

Application
Electronics And Micro-Electronics
Sub-application
electrochemical battery storage
Hydrogen supply chain stage
All components affected
electrochemical battery system
Location type
Confined
Operational condition

Emergency & Consequences

Number of injured persons
0
Number of fatalities
0

Event Nature

Release type
gas
Involved substances (% vol)
H2 100%
Presumed ignition source
Not reported

References

Reference & weblink

Event description in the French database ARIA<br />
https://www.aria.developpement-durable.gouv.fr/accident/28822/<br />
(accessed October 2020)<br />

JRC assessment